Wolf Gourmet WGBL100S Power Cord Replacement
ID: 108565
Description: If your power cord is broken and your blender...
Steps:
- With the bottom of the blender facing up, use a Phillips #2 screwdriver to remove the 4, 1/2 inch long screws in the corners of the device.
- Ensure the blender is off and unplugged before starting.
- Using a metal spudger, pry up one side of each of the rubber feet.
- Note that one side of each foot is glued down; pry up the non-glued side.
- Using the same Phillips #2 screwdriver, unscrew the 1/2 inch long screw under each of the feet.
- Pull off the base and remove the plastic housing underneath.
- On the underside of the base, unscrew the three 3/8" long screws on the plastic piece holding the power cord in place using a Phillips #1 screwdriver.
- Pull the plastic cover off.
- Using a wire cutter, cut the three wires of the power cord.
- Pull the cut power cord through the base.
- Then thread the replacement cord back through and re-attach the plastic cover.
- Strip about an inch of insulation off of the snipped power cord and your replacement cord.
- Twist each strand of wires together to keep them neat.
- Twist together the wires from the replacement cord to the wires still attached to the blender.
- Solder the connection if possible.
- Wrap all the connections in electrical tape or heat shrink tubing.