Fujifilm FinePix HS30EXR Discharge Flash Replacement

ID: 115414

Description: This guide serves to help the user replace the...

Steps:

  1. Flip the camera so that the bottom is facing upwards.
  2. With the Phillips #00 screwdriver, remove all four screws.
  3. Step image
  4. Flip the camera so that it is now on the right side.
  5. With the Phillips #00 screwdriver, remove all four screws.
  6. Step image
  7. Flip the camera so that it is now on the left side.
  8. Move or remove the flap hiding the camera ports.
  9. With the Phillips #00 screwdriver, remove all screws.
  10. Step image
  11. Flip the camera so that it is now on the top side.
  12. With a spudger, pry off the highlighted metal piece of the camera.
  13. Step image
  14. With the Phillips #00 screwdriver, remove all four screws.
  15. Step image
  16. Pull the LCD screen up and out of the way.
  17. With the Phillips #00 screwdriver, remove the screws.
  18. Step image
  19. With a spudger, pry off the frame.
  20. If the frame does not easily dislodge after a few attempts, ensure that all screws are taken out.
  21. Step image Step image
  22. Slowly and carefully pull the frame away to have a better view of the inside.
  23. Step image
  24. Peel back (or off) the black tape to expose more of the inside of the camera.
  25. Flip the white switch of the highlighted chamber up, and that should unlock the ribbon cable from its compartment.
  26. To see if this worked, gently pull the ribbon cable out of the compartment. It should come out without force.
  27. Step image
  28. Disconnect the ribbon cable.
  29. Step image
  30. With the Phillips #00 screwdriver, remove all five screws.
  31. Remove the metal casing.
  32. Step image
  33. With the Phillips #00 screwdriver, remove all screws.
  34. Step image
  35. Ensure the four ribbon cables are disconnected from the motherboard.
  36. Be aware, one is under the black tape.
  37. Step image
  38. Begin desoldering all four highlighted areas.
  39. Step image
  40. Remove the motherboard.
  41. Step image
  42. Remove the discharge flash by giving it a light tug. It is held in place with glue.
  43. Replace the old flash bulb with a new one, and begin the reconstruction of the device.
  44. Step image