SRM Power Meter Battery Replacement
ID: 130226
Description: In case you are far away from Germany or don’t...
Steps:
- Remove the chain rings. On some models there are little screws to open the cap. On my FSA Model there is a tab to pop open the cap.
- Make sure the seals stay intact.
- There are 2 batteries glued in. They are connected with a power cable that has a little 2 pin plug.
- ATTENTION: Make sure you don't damage the thin cooper wires marked in yellow.
- Unplug the batteries from the circuit board. (red)
- With the solder gun remove the cables from the old batteries. Make sure not to melt the cables or plug.
- My batteries had mounting pins attached to the silver side. They have to be remove with pliers.
- The terminal pins have to be bent straight.
- Finally the pins have to be cut to the same length as the old batteries.
- Add heat shrink to cables and solder them to battery. Red to (+) and black to (-)
- Push the heat shrink up to cover the entire pin and soldering connection.
- Twist the wired back together gently.
- Attach the new batteries. There is a + on the circuit board on the side where the red wire goes.
- Push the batteries gently back into place.
- Connect the power meter and check the battery status of the sensor. On my Garmin I see NEW.