Honda 6500 Watt Generator EG6500CL AT Automatic Voltage Regulator Replacement

ID: 135760

Description: This guide shows how to remove and replace the...

Steps:

  1. Before you work on the device, make sure to switch the engine off.
  2. Switch the circuit breaker off.
  3. Step image Step image
  4. Grab the plastic housing at the end of the spark plug wire.
  5. Pull firmly to disconnect the wire from the spark plug.
  6. Step image Step image
  7. Twist the fuel valve clockwise into the cutoff position.
  8. Step image Step image
  9. Remove the five Phillips screws securing the front panel:
  10. Two 35 mm screws
  11. Two 20 mm screws
  12. One 15 mm screw
  13. Step image
  14. Carefully pull the front panel away from the generator in order to access the internal components.
  15. Do not attempt to remove the panel—it is still connected by many wires.
  16. Step image Step image Step image
  17. Use a flathead screwdriver to unclip the green ground wire from its socket.
  18. Step image Step image
  19. Use a flathead screwdriver to press and release the two plastic tabs securing the AVR module.
  20. Step image Step image Step image
  21. Carefully slide and remove the automatic voltage regulator out of its recess.
  22. Step image Step image Step image
Back