Description: (1) Pry up the frame all around the perimeter....
Steps:
- Pry off the frame around the entire perimeter.
- Unplug the 3 connectors shown in the photo and detach them from the adhesive along the cable.
- When releasing the cables, a gentle pull is sufficient; the adhesive strips can be reused later.
- Leave the blue socket attached to the power supply and lift the power supply off the screen panel; if possible, continue working on a different surface and turn the power supply over to do so.
- Remove the black plastic cover (simply pull it out) and locate the solder points shown.