Honda 3000 Watt Inverter Generator EU3000IS1AWK Air Cleaner Housing Replacement

ID: 136199

Description: This guide shows how to remove and replace the...

Steps:

  1. Before you begin, make sure the generator is off and cool to the touch.
  2. Use a large flathead screwdriver to unlock the maintenance cover.
  3. Open the maintenance cover.
  4. Step image Step image
  5. Use a Phillips screwdriver to remove the screw securing the spark plug cover.
  6. Remove the spark plug cover.
  7. Step image Step image
  8. Grab the plastic housing at the end of the spark plug wire.
  9. Pull firmly to disconnect the wire from the spark plug.
  10. Step image Step image
  11. Turn the fuel valve to the cutoff position.
  12. Step image Step image
  13. Unlatch the four clips securing the air cleaner cover.
  14. Remove the air cleaner cover.
  15. Step image Step image Step image
  16. Remove the air cleaner filter from the housing.
  17. Step image Step image
  18. Pull and disconnect the breather tube from the top corner of the air cleaner housing.
  19. Step image Step image
  20. Pull and disconnect the lower tube from the bottom corner of the air cleaner housing.
  21. Step image Step image
  22. Use a 10 mm socket to remove the three fasteners securing the air cleaner housing:
  23. Two 10 mm nuts
  24. During reassembly, tighten these nuts to 6.3 ft-lb (8.5 N-m).
  25. One 10 mm bolt
  26. Step image
  27. Pull the housing out slightly from its recess.
  28. The housing still has tubes clipped to it.
  29. Step image Step image
  30. Use a flathead screwdriver to pry and unclip the tube from the air cleaner housing.
  31. Step image
  32. Remove the air cleaner housing.
  33. Step image
Back