Steps:

  1. Switch off the machine so that the brew group moves to the removal position.
  2. Unplug the power cord.
  3. Take out the water tank and the pulp bowl.
  4. Open the hatch behind the water tank.
  5. Press the two red buttons together and pull out the brew group.
  6. Step image Step image Step image
  7. Lay the device on its side so that you can easily access the upper brewing plunger.
  8. Unscrew the two Phillips screws.
  9. Remove the black plastic cap from the top brew plunger, remembering the orientation for later reassembly.
  10. Clean everything under the cap and the cap itself.
  11. Lightly grease the new O-ring with food grade silicone grease and replace the top O-ring.
  12. Screw the cap back on.
  13. Step image
  14. Unscrew a total of four Phillips screws on the front and back of the brew group.
  15. Step image Step image
  16. Now carefully separate the front and back.
  17. Look out for the tiny black rubber buffer with a pentagonal profile. This is the stop for the trester bucket. It often falls out. Replace it between the two halves of the housing when reassembling.
  18. The pomace shovel at the top is under tension from a torsion spring, pay attention to this when removing it.
  19. When assembling, you first have to insert the spring of the shovel, then place the shovel wide open on it and then swivel it in. Only then can the two halves be pressed together again.
  20. Note the position of the two levers with the teeth in the lower area and the position of the piston for later assembly. Then pull them off.
  21. Figures 2 and 3 show the two end positions of the levers. Fig. 2 shows the position when the piston is flush at the top.
  22. Step image Step image Step image
  23. Push the plunger up and out.
  24. Remove the old O-rings.
  25. Step image Step image
  26. Unscrew the Phillips screw on the brewing sieve.
  27. Take off the brew sieve.
  28. Step image Step image
  29. The crema valve is located in the bottom of the flask under a plastic cap. You should also take this opportunity to inspect and clean it.
  30. The cap is very tight and difficult to remove.
  31. Pry the cap out with a sharp tool. Alternately apply the tool to the nubs. You need a lot of patience.
  32. Take out the parts of the crema valve.
  33. Thoroughly clean all parts of the brew group. Install two new O-rings on the piston.
  34. Lightly grease the O-rings and the axles of the moving parts with food grade silicone grease.
  35. Step image Step image
  36. The piston must be inserted as shown, the teeth must fit into the rack. The piston then closes flush at the top.
  37. Check that the piston moves smoothly and reaches both end positions correctly. Make sure that the lever for the coffee ejector rests on the inside of the small rubber buffer and is easy to move.
  38. Step image Step image Step image