Furnace Humidifier Evaporator Pad Replacement

ID: 146863

Description: Furnace humidifiers are built in almost every...

Steps:

  1. Turn off the humidifier. (Set the humidistat to 0% humidity)
  2. Step image
  3. Remove the nuts and clips holding the top cover of the cabinet assembly to the bottom cabinet housing.
  4. Step image Step image
  5. Remove the side clips or fasteners.
  6. Step image
  7. Use an adjustable wrench to loosen the nut which holds the water distributor tube and swing the tube out of its secured place.
  8. Step image
  9. Remove the top of the bottom cabinet housing and take out the evaporator pad.
  10. Step image
  11. Place the new evaporator pad inside the clean bottom cabinet.
  12. The sides should guide it into the correct position.
  13. Step image Step image
  14. Replace the clips, nuts, and bolts removed in steps 2 through 4.
  15. Step image
  16. Turn on the humidifier.
  17. Step image