Syntus ST150 Ultrasonic Plate Replacement
ID: 149317
Description: An ultrasonic plate in an essential oil...
Steps:
- First, make sure the water tank inside the diffuser is completely dry to avoid any water from contacting the internal components.
- Make sure the diffuser is disconnected from the power source to avoid electrical hazards.
- With a Phillips #1 screwdriver, remove the three 10 mm screws on the bottom of the diffuser.
- Lift the water tank while holding the base of the diffuser.
- Disconnect the three cables form the board.
- Make sure when reassembling the diffuser to plug in each cable to its assigned port.
- To separate the board from the water tank, unscrew the three Phillips #1 10 mm screws securing the board.
- With a Phillips #0 screwdriver, remove the three 7 mm screws from the ultrasonic sensor cover.
- Remove the cover to expose the ultrasonic sensor.
- Detach the ultrasonic sensor from the water tank.
- Detach the ultrasonic sensor connector from the board.
- Remove the rubber cover from the ultrasonic plate.
- Now you can replace the ultrasonic plate of your diffuser.