Vicks FilterFree Plus Power Cord Replacement
ID: 160291
Description: Replacing the power cord on your Vicks FilterFr...
Steps:
- Ensure the device is clear of water before disassembling.
- Orient the device so the nozzle is facing the ceiling.
- Twist off the primary water holding cap.
- Place the device upside down so that the tank cap is facing you.
- Use your hands to twist the tank cap and remove it from the device.
- Remove the three screws from the base of the device using a T20 Torx screwdriver.
- Remove the base of the humidifier to access the components.
- Gently remove the inner shield for the primary board to access the wiring for the humidifier.
- Remove the two Phillips screws holding the power cord in place.
- Unclip the power cord from the motherboard.