Description: If your humidifier is not producing any mist,...
Steps:
- Ensure the device is clear of water before disassembling.
- Orient the device so the nozzle is facing the ceiling.
- Twist off the primary water holding cap.
- Place the device upside down so that the tank cap is facing you.
- Use your hands to twist the tank cap and remove it from the device.
- Remove the three screws from the base of the device using a T20 Torx screwdriver.
- Remove the base of the humidifier to access the components.
- Gently remove the inner shield for the primary board to access the wiring for the humidifier.
- Remove the square heat shield by unscrewing the two screws using a Phillips #1 screwdriver.
- Unclip the mist maker power cord.
- Remove the triangle shaped heat shield by unscrewing the three screws using a Phillips #1 screwdriver.
- Take note of the mist maker's orientation for reassembly.
- Remove the mist maker from the device.