Vicks FilterFree Plus Ultrasonic Mist Maker Replacement

ID: 160435

Description: If your humidifier is not producing any mist,...

Steps:

  1. Ensure the device is clear of water before disassembling.
  2. Orient the device so the nozzle is facing the ceiling.
  3. Twist off the primary water holding cap.
  4. Step image
  5. Place the device upside down so that the tank cap is facing you.
  6. Use your hands to twist the tank cap and remove it from the device.
  7. Step image Step image
  8. Remove the three screws from the base of the device using a T20 Torx screwdriver.
  9. Remove the base of the humidifier to access the components.
  10. Step image Step image
  11. Gently remove the inner shield for the primary board to access the wiring for the humidifier.
  12. Step image Step image
  13. Remove the square heat shield by unscrewing the two screws using a Phillips #1 screwdriver.
  14. Unclip the mist maker power cord.
  15. Step image Step image Step image
  16. Remove the triangle shaped heat shield by unscrewing the three screws using a Phillips #1 screwdriver.
  17. Take note of the mist maker's orientation for reassembly.
  18. Remove the mist maker from the device.
  19. Step image Step image Step image