Melitta Caffeo Barista T Grinder removal

ID: 163377

Description: These instructions may also help with other...

Steps:

  1. Never forget: Remove the cable from the powerplug
  2. Remove all the parts
  3. Step image
  4. The backside is fixed with seven Torx T10 screws. Unscrew them
  5. Get the Backside of. It should be a bit stuck.
  6. Step image Step image
  7. Pull the powder compartment up.
  8. Pull one of the sides of the Powder compartment out of the hinge and loosen the lid.
  9. Remove the powder compartment
  10. Step image Step image Step image
  11. In the powder compartment, you should see a rubber cover. Loosen the rubber cover with the appropriate tools.
  12. There should also be a Torx T10 screw. Unscrew it
  13. Step image Step image Step image
  14. The upper cover with the brewing unit is held up from three clamps. These can be reached through a slit.
  15. Press these clams with a flat scredriver in and pull the upper cover up, until the clamps loosen.
  16. Step image Step image
  17. On the side that has a a watertank you can find 2 other clamps
  18. Press these clamps with a flat scredriver in and pull the cover up until they loosen
  19. Lift the upper cover and the backside up, hook it on the front edge and remove them
  20. Step image Step image Step image
  21. Push the right and the left side panel back, then pull the lower edge out and pull the side panel out.
  22. This could be a bit stuck
  23. On the side panel with the watertank, there should be a supply hose attached to a cable that connects the water-level sensore. loosen them
  24. Hint: the side panel doesn't have to be removed completely for each repair.
  25. Step image Step image
  26. Unscrew the 3x Torx T10 screws that secure the bean compartment.
  27. Remove the bean compartment upwards.
  28. When assembling, make sure that the slider for setting the bean type engages properly.
  29. Step image Step image
  30. Take out the two foam dampers and the black rubber bean feeder.
  31. Step image Step image Step image
  32. Unscrew the Torx T10 screw that secures the powder chute.
  33. Lift out the powder chute.
  34. Step image Step image
  35. The grinder is fixed with 3x Torx T10 screws. Unscrew them.
  36. Now the grinder is loose. Press it inward a little so that the previously mentioned adjustment lever is free and lift the grinder upward a little.
  37. If you want to replace it completely, you still need to disconnect the two cables, if you just want to clean it or replace the grinding stones, it is not necessary.
  38. Step image