Reverse Osmosis Filter Reservoir Pressure
ID: 163426
Description: Repressurize your reverse osmosis (RO) filter...
Steps:
- Disconnect the filter from the main water supply
- Typically this is a needle valve
- Open the main valve to release the pressure from the reservoir/bladder.
- Leave this open until you are ready to repressurize the reservoir
- Remove the cap from the Schrader valve (or other) and connect an air pump
- Most reservoirs have a standard Schrader valve
- For a standard Schrader valve, connect a bicycle air pump to the valve stem
- Use the air pump to (Gently!) force all of the water from the reservoir
- Be careful to not over pressurize the reservoir/bladder! This may damage the filter!
- (Gently!) pump your air pump as the water is drained from the reservoir
- Continue (Gently!) pumping, to ensure all of the water is emptied from the reservoir.
- Easy rule of thumb: if your pump has a built-in pressure gauge, generally avoid more than 10 to 20 PSI
- Close off the output valve for the reservoir
- For most RO unit reservoirs, this is a ball valve on the top of the reservoir
- Release any over-pressure of the reservoir
- The reverse end of most tire pressure gauges, a flathead screwdriver, or your car keys, are good tools to easily release pressure from a standard Schrader valve
- Use your air pump to repressure the, now empty, reservoir
- Most reservoirs operate between 5 and 8 PSI
- Consult the owners manual for your specific filter to find the optimum operating pressure for the reservoir
- With the reservoir repressurized to the specified pressure, reopen the ball valve
- Fin.