LG Refrigerator Ice Auger Motor Run Capacitor Replacement
ID: 167761
Description: Use this guide to replace the ice auger motor...
Steps:
- Unplug your refrigerator before you begin your repair.
- If you are testing or repairing the following items, you may also need to shut off and disconnect the water supply:
- Condenser fan motor
- Compressor motor and thermal overload device
- Water supply valve assembly
- Use a Phillips screwdriver to remove the screws securing the control board cover.
- Tilt the top edge of the cover toward you and lift it off.
- Squeeze and pull the connectors to disconnect them:
- Connectors from the control board
- Connectors from the refrigerator
- Some connectors can remain connected as the wires attached to them don't get in the way. There is no harm if they are disconnected. Remember to reconnect them if disconnected.
- Reposition the wiring harness away from the capacitor.
- Pull the two connectors straight off the capacitor to disconnect it.
- Handle the capacitor carefully as it may still be charged, and can give a dangerous and painful electrical shock. Avoid touching the terminals with your fingers or hands.
- Information on capacitor safety.
- Use a Phillips screwdriver to remove the screw securing the capacitor to the refrigerator.
- Remove the capacitor.