ORFELD EV-660-S222 Charging Port Replacement

ID: 168044

Description: If your ORFELD EV-660 has stopped charging...

Steps:

  1. Separate the dust cover and the motor from the vacuum body by pressing the eject button.
  2. Step image
  3. Place the vacuum on its side, with the screws facing towards you.
  4. Remove the 11.5 mm screws using a Phillips #1 screwdriver.
  5. Step image Step image
  6. Using tweezers, remove the sticker connecting the two halves.
  7. Use the opening pick to gently separate the top half and the bottom half of the vacuum.
  8. Press the blue buttons near the sides of the battery LEDs to remove the top half.
  9. Step image Step image
  10. Slide out the charging port.
  11. Step image Step image
  12. Lift the battery slightly to reveal the pin connectors.
  13. Gently remove the four-pin connector connecting the charging port.
  14. Step image Step image Step image
Back