Ubiquiti 48 port switch (US 48 G1) power supply replacement
ID: 169286
Description: A relatively common failure on Ubiquiti...
Steps:
- Identify the four screws (two at the back, two at the bottom) holding the switch closed. One is hidden behind a sticker.
- You do not need to remove the rack brackets
- Use a PZ2 screwdriver to remove the screws
- Slide the lid a short distance towards the front to open the switch.
- Identify the power supply. It is the yellow separate board at the bottom.
- There may be burn marks on the power supply from the failure.
- Remove it from the switch (4 screws, PZ2)
- Save the power supply and screws. You will need them later.
- Unbox the replacement Powersupply
- Unscrew the two screws at the front, and the two at the back to remove the top metal screen
- Finally removed the two back screws to free the board from the bottom metal screen
- Insert the replacement Powersupply in the switch, and secure it with the original 4 screws
- Dimensions of the replacement power supply should be identical to the original one.
- The main power connector should fit on the new power supply.
- Unsolder the 24v leads from the old power supply.
- Identify the positive and negative output on the new power supply. On this one, positive is at the bottom of the picture.
- Solder in the 24v leads on the new power supply
- Solder in the blue (+) lead on the bottom of the output connector
- Solder in the black (-) lead on the top of the output connector
- Alternatively, get a proper connector that fits on the power supply.
- Finally, connect the 24V on the main board