Nordgas Atlantis 25 hww Heating Repair (error code E 18)

ID: 179042

Description: The gas boiler went into fault mode with error...

Steps:

  1. Release the two screws at the front bottom and tilt the cover away.
  2. Step image Step image
  3. First, close the supply and return shut-off valves, open the bleed screws (as described on page 31 of the manual), and drain the water from the heater by loosening the drain screws.
  4. Step image
  5. The front part of the pump can be separated from the pump housing after you release the 4 screws.
  6. (Point 1 in the second image is the pump bleeder screw)
  7. Step image Step image
  8. The impeller with the bearing housing can be pulled out from the front part of the pump. After measurements, it turned out that the impeller was protruding too far. I stood the part with the impeller on the table and tapped the opposite side lightly with a hammer. The impeller could be driven in by about 4 mm.
  9. After reassembly, follow page 31 of the manual and reopen the flow and return shut-off valves. After testing, the heating boiler is working perfectly again.
  10. Finally, a word on the dangers. Since this is a gas-fired boiler, I would not carry out a repair involving the gas path, but would commission a qualified heating technician to perform the repair.
  11. Step image