Milwaukee 6130-33 Safety Brush Springs Replacement

ID: 179094

Description: If your Milwaukee (6130-33) device is producing...

Steps:

  1. Hold the device with the cord facing upwards and the bottom side facing down.
  2. Remove the 4 mm TR20 Torx screws from the exterior case.
  3. Step image Step image
  4. Remove the two 4 mm TR20 Torx screws to detach the clamp from the cord set.
  5. Step image Step image
  6. Remove the two 3.5 mm TR10 Torx screws to access the wiring.
  7. Wiring can be damage or worn, take caution when handling the wires.
  8. Step image Step image Step image
  9. Remove both 3.5 mm TR10 Torx screws from the carbon brush locks.
  10. Turn over the device and perform the same process on the opposite side.
  11. Step image Step image Step image
  12. Remove both springs by pulling outwards from the rotor.
  13. When removing, pull on the carbon casing to avoid harming both yourself and the device.
  14. Step image Step image
  15. Using a pair of pliers, squeeze the black cord.
  16. Remove by pulling the black wire attached to the brush casing.
  17. Step image Step image