Thermo Electric Wine Cooler repair

ID: 181695

Description: Thermoelectric coolers are commonly used in...

Steps:

  1. Remove the screws from the back of the cooler then remove the metal plate from the back of the unit to expose the circuit board.
  2. Step image
  3. This board has 9 connectors. Some of the connectors are at obvious locations such as the power input connector on the right side of the board labeled 1. Other connectors are color coded to their female receivers. My board has extra female connectors indicating this board is used on various units.
  4. I label any connectors that need identification to eliminate improper placement.
  5. Step image Step image
  6. Two capacitors show electrolyte deposits that have leaked through the top of the component. That is a typical indicator of a bad capacitor.
  7. Step image Step image
  8. Remove the faulty capacitors using a solder iron and a copper solder wick.
  9. One of the failed capacitors is 25 volt 470 µf.
  10. Capacitors are temperature sensitive and are frequently marked with an acceptable temperature range. Capacitors generate heat as they operate which contributes to their eventual failure.
  11. Step image Step image Step image
  12. I tested the 470 µf capacitor and found that it had a reading of 237 µf. It isn't really necessary to test the removed capacitor. If its leaking it needs to be replaced.
  13. Step image
  14. Not all capacitors are polarized but polarized capacitors clearly identify the negative connector.
  15. The correct orientation is usually indicated on the circuit board.
  16. Step image Step image
  17. Replace the faulty capacitor with a new unit of a similar rating.
  18. Step image Step image
  19. Put the circuit board back, properly connect the wires and with luck you will again be cooling wine.
  20. Step image