Philips HQ6970 disassembly (housing, circuit board, motor, gearbox)
ID: 182402
Description: Here is an almost complete disassembly of the...
Steps:
- Remove three Torx T8 screws.
- Use both thumbs to grasp the top and bottom of the case near the power plug.
- Move the two parts apart. On the razor head, the two parts move like a door hinge.
- Remove the black cover with the trimmer and put it aside.
- First lever into the gap oft the left side with the pointed end of a spudger,
- then right so that the plastic clips come loose.
- Remove the clamp when both plastic clips are unlocked.
- Remove two Torx T8 screws.
- Caution: The head section with motor is connected to the circuit board via the motor's electrical connections.
- Hier Übersetzung einfügen
- Hier Übersetzung einfügen
- Hier Übersetzung einfügen
- Use a spudger to carefully lift the charging port slightly until you can lift the circuit board with your hand.
- The circuit board is slightly guided in the white housing.
- After lifting the circuit board, pull it backwards in the direction of the arrow.
- Now lift the circuit board with motor out of the white housing.
- There are three plastic clips.
- Carefully unlock all three plastic clips one after the other.
- Carefully remove the black gearbox cover.
- Remove the four gears and the eccentric coupling for the trimmer.
- The dirt has penetrated into the transmission. If you've already gotten this far and your transmission is dirty, it's best to clean it and then re-grease it.
- Here some steps later.
- Almost all components were connected to each other with plastic clips.