Arlo Pro 2 Base Station Sensors Replacement

ID: 185709

Description: If you are trouble connecting Arlo Pro 2 base...

Steps:

  1. Use a TR10 Torx screwdriver to remove the two 10 mm screws on the side of the base station, above the USB ports.
  2. Pull apart the top case from the bottom.
  3. This may require some force as there are internal catches.
  4. Step image Step image Step image
  5. Use a TR10 Torx screwdriver to remove the two 10 mm screws to disconnect the motherboard from the base casing.
  6. The motherboard is connected to the USB ports; when removing it be careful to gently remove the USB ports from their cavities to avoid any damage.
  7. Step image Step image Step image
  8. Follow the black wire running from each thin metal sensor to the motherboard; they will be connected under a piece of black tape.
  9. Pull back the black tape to see where the wire you are following attaches to the motherboard.
  10. Pull up on the coaxial connector to disconnect the wire from the motherboard.
  11. Step image Step image Step image
  12. Snake the wires through any place where it goes through the plastic casing.
  13. Gently pull the metal sensor away from the plastic casing to fully disconnect it from the motherboard.
  14. Step image Step image Step image
Back