Steps:
- With the vacuum in an upright position, press the latch on the rear of the spine to remove the handle from the vacuum.
- Use a Phillips #2 screwdriver to remove the five 20.7 mm screws on the underside of the brush roll cover.
- Use a pry tool or flathead screwdriver to disengage the two retaining clips securing the brush roll cover.
- Remove the brush roll cover.
- Disconnect the main black hose from its lower attachment point.
- Use a Phillips #2 screwdriver to remove the two 20.7 mm screws from the lower hose attachment point.
- Use a Phillips #2 screwdriver to remove the four 20.7 mm screws on the upper cover plates.
- Remove the two upper cover plates.
- Gently pull the top half up and to the side away from the drive shaft to separate both halves.
- Pull the belt through the socket, and remove the belt from the drive shaft.
- Push the button on the canister to remove it from the spine.
- Set the canister to the side.
- Remove the one 20.7 mm screw with a Phillips #2 screwdriver.
- Separate the spine from the motor.
- Remove the four 2.7 mm screws with a Phillips #2 screwdriver.
- Press down on the red lever to access another 20.7mm screw. Remove the screw with a Phillips #2 screwdriver.
- Separate the halves.
- Take care not to strain the connected cables.
- Unwind the power cable from its post, and gently pull the motor out of the casing.
- By taking the motor out of its casing, the cover of the switch becomes exposed.
- Use a Phillips #2 screwdriver to remove the 20.7 mm screw from the cover.
- Gently remove the cover.
- Gently disconnect the motor from the connector.
- Remove the motor.
- Identify the two wire connection points.
- Press down on the connection points and slide them out.
- When both points are separated, you should have 3 pieces: the power cable, the switch, and the motor.