Pentax PZ-1p Body Panel Removal
ID: 194109
Description:
Steps:
- Unlatch battery compartment door.
- Remove one 1.7 x 4.0 mm screw.
- Remove six 1.7 x 2.5 mm shoulder screws.
- Remove one 1.7 x 2.5 mm long shoulder screw.
- The bottom cover may be adhered with double sided tape in some locations. Use a spudger to gently work it loose.
- Check that the physical panorama switch on the bottom cover and the electrical switch mate properly.
- Push button to pop up the flash.
- Remove two 1.7 x 2.5 mm screws.
- Detach snaps by lifting the side of the flash cover, bending it up and away from the housing.
- Push flash back down to the stored position.
- Remove two 1.7 x 2.5 mm screws underneath the pop-up flash.
- Remove one 1.7 x 2.5 mm panhead screw above the pop-up flash.
- Remove two 1.7 x 2.5 mm shoulder screws near the eye piece.
- Remove two 1.7 x 2.5 mm shoulder screws by the strap lugs.
- Remove one 1.7 x 6.0 mm screw inside the battery compartment.
- Lift off the top cover.
- Check that the physical power switch and the electrical power switch are both in the same position before installation.
- Push the release latch down to remove the film door.
- Peel off rubber covering from grip.
- Remove one 1.7 x 5.0 mm screw.
- Lift off the front body panel.