Steps:

  1. Separate the filter from the electronics housing by pressing the grey latch.
  2. Step image
  3. Unscrew the electronic housing screws using a Phillips #00 screwdriver.
  4. Remove the front panel.
  5. Step image
  6. Identify the switch within the internal electronics.
  7. The switch is connected to the rest of the circuit via two terminals with one terminal covered by a blue heat shrink tube.
  8. Step image Step image
  9. Remove the switch from the clasps. Use a spudger to push down on the metal tab and pull the switch terminal away.
  10. When removing the blue heat shrink side just pull the heat shrink below the metal terminal.
  11. Step image Step image
  12. Reattach the new switch.
  13. It should just slide in when the terminal and clasps are aligned.
  14. Step image
  15. Position the switch in the plastic slot in the housing.
  16. Step image
  17. Reattach the outer panel of the electronic housing.
  18. Ensure that the switch is flush against both sides.
  19. Step image
  20. Reattach the electronics to the filter component of the vacuum and test the switch by powering the vacuum and turning it on and off.
  21. Step image