How to Use Diagnostic Modes on a Roper Washing Machine
ID: 207277
Description: [youtubevideo|X9zNsGhmeeM]Use the hidden...
Steps:
- Remove the harness plate screw and two top screws on the rear panel with a quarter inch hex driver.
- Pull the lid toward you, lift upward, then push it back so it pivots on the rear metal tabs.
- Tape the lid down before lifting to prevent accidental slamming.
- Support the raised top so it cannot fall backward.
- Reach inside the front left corner and remove the folded technician’s sheet.
- Rotate the main cycle knob counter-clockwise until it rests at the 12 o’clock position after one full turn.
- Turn the knob right three clicks, left one click, then right one click, pausing about half a second between moves.
- All green status lights flashing together confirm successful entry into diagnostics.
- Turn the knob clockwise to scroll through the available service options.
- The menu order is Error Code Check, Automatic Test, Manual Test, and Recalibration.
- Stop at the Cycle Complete lamp, then press Start to enter error code mode.
- After the lamps flash, rotate the knob clockwise to display up to four stored fault codes.
- Move to the fifth position and hold Start for about five seconds to erase all codes.
- A lit Sensing Fill lamp means the code prefix is F; if it is dark the prefix is E.
- Add the illuminated number lamps to form the full code such as F0E5.
- Refer to the technician sheet if a displayed code is not listed here.
- Treat codes as clues because wiring or other issues can trigger them even when a part is still good.
- Rotate to Automatic Test and press Start to run a three-minute check of every major component.
- The lid lock engages, so leave the top loose or remove the striker for observation.
- Remove the two Torx screws, slide the striker from the lid, and insert it into the lock to fool the switch.
- Opening the lid during high-speed spin can cause injury or damage.
- Press Start to enter Manual Test then turn the knob to the function you want to evaluate.
- Press Start again to begin the action and press it once more to stop it.
- Select Lid Lock first when you plan to run spin or agitation tests.
- Some knob positions are placeholders for features not installed on your model; check the tech sheet.
- Hold Start for three to four seconds to exit Manual Test and return the washer to standby.
- From diagnostics rotate the knob four clicks clockwise until only the Rinse lamp is lit and press Start.
- The washer recalibrates motors sensors and shift mechanisms in roughly two and a half minutes.
- All panel lamps turn off when calibration is complete and the washer is ready for normal use.
- Lower the top onto the rear hinges slide it forward and reinstall the three back screws.
- Refit the lid striker if it was removed and take off any tape from the lid.