How to Use Diagnostic Mode on a Kenmore Washing Machine
ID: 207278
Description: [youtubevideo|X9zNsGhmeeM]Use the washer’s...
Steps:
- Use a quarter-inch hex head screwdriver to service the washer.
- Remove the harness plate screw and the two top panel screws from the rear of the washer with the quarter-inch hex driver.
- Pull the lid toward you, lift it upward, then push it back to let the top panel pivot on its rear hinges.
- Tape the washer lid closed before lifting the top panel to keep it from swinging open.
- Rest the open top against a wall or brace it with a support so it cannot fall while you work.
- Remove the technician sheet from the front left corner inside the cabinet and keep it handy for code reference.
- With power connected rotate the cycle knob counter-clockwise until it reaches the 12 o’clock position completing one full turn.
- Turn the knob right three clicks, left one click, then right one click, pausing about half a second between each movement.
- Confirm entry when every status LED flashes together.
- Rotate the knob clockwise to scroll through Error Code, Automatic Test, Manual Test, and Recalibration modes.
- Stop when only the Cycle Complete LED is lit and press Start to enter the error code menu.
- Wait for the LEDs to flash once, indicating stored faults are ready to display.
- Turn the knob clockwise to view each of the four most recent fault codes.
- If the Sensing Fill LED is lit the code begins with F; if it is dark the code begins with E.
- Add the numbers shown by the other lit LEDs to complete the code and record it for spin or drain troubleshooting.
- After the fourth code turn the knob once more, then press and hold Start for about five seconds while all LEDs flash to erase the memory.
- Rotate to Automatic Test and press Start; the washer will fill, agitate, drain, and spin through every major function in roughly three minutes.
- The lid lock engages during this test, blocking your view unless the lock is bypassed.
- Remove the two Torx screws securing the lid striker, slide the striker off, and insert it into the lid lock.
- Opening the lid during high-speed spin can cause injury or damage; observe at your own risk.
- Watch and listen as the washer moves through each step to identify any component that fails to actuate, fill, drain, or spin.
- Select Manual Test, press Start, then rotate the knob to the function you wish to test individually.
- Choose Lid Lock first when you need to run agitation or spin tests.
- Press Start to begin the selected action and press it again to stop when finished.
- Hold Start for three to four seconds to cancel manual mode and return the control to standby.
- From diagnostics rotate the knob four clicks clockwise until only the Rinse LED remains lit, then press Start.
- Let the recalibration run for about two and a half minutes until all LEDs turn off.
- Lower the top panel onto the cabinet, slide it forward to seat the hinges, and tighten the two top panel screws and harness plate screw.
- Remove the tape, move the washer back into place, and resume normal use with diagnostics complete.