How to Fix the Frigidaire Dryer DR Error Code
ID: 221319
Description: [youtubevideo|hkEvAXp9kEY]Use this guide to...
Steps:
- Unplug the dryer before opening the cabinet or touching the door-switch terminals.
- Turn off the circuit breaker if the plug is not reachable or the dryer is hardwired.
- Never use the ohms setting on a powered circuit, because this can shock you or damage the multimeter.
- Let the dryer cool if it was recently running.
- Shut off the gas valve before moving a gas dryer for access.
- Select a cycle and press Start.
- If the dryer shows DR, it is not seeing a closed door and will not run.
- Close the door fully and press Start again.
- If DR still flashes with the door closed, check the door closure, the door switch, and then the control board.
- Use this closed-door power path as your reference: L1 → thermal limiter → door-switch common → normally open terminal → motor relay on the control board.
- With the door open, the switch routes power from common to the drum light.
- With the door closed, the switch should route power from common to normally open.
- If the dryer shows DR, the control is still getting power through the thermal limiter. That leaves the closed-door switch path or the control board as the likely fault.
- Close the door firmly and make sure it stays flush with the front of the dryer.
- Do not force the door closed, because that can damage the catch or the door.
- Press Start and watch for the DR code.
- Inspect the small catch at the top if the door does not stay completely closed.
- A broken catch can make the door look closed without pressing the switch far enough.
- Press gently on the door while you press Start.
- If light pressure lets the dryer start, repair or replace the door catch before testing the switch.
- Open the door and check whether the drum light turns on.
- Do not stop the diagnosis just because the drum light works.
- The switch can still power the light with the door open while failing between common and normally open.
- Test common to normally open to confirm that the closed-door contact works.
- Unplug the dryer again if it is still connected.
- Expose the door-switch terminals enough to reach them with the multimeter probes.
- Identify the common and normally open terminals on the switch.
- Touch one multimeter probe to common and the other to normally open.
- Set the multimeter to ohms.
- Close the door so the switch should be activated.
- Read the multimeter while the probes stay on common and normally open.
- OL means open line, so the switch is not making the closed-door connection.
- Replace the door switch if the meter shows OL with the door closed.
- A reading around 0.1 ohm with the door closed means the switch is good.
- Confirm that the door closes properly.
- Confirm that the door switch reads about 0.1 ohm between common and normally open with the door closed.
- Reconnect any wiring you disconnected during the switch test.
- Do not power the dryer with exposed wiring or loose terminals.
- Plug in the dryer, select a cycle, and press Start.
- If DR remains with a properly closed door and a good switch, unplug the dryer and replace the control board.
- At that point, the control board is not reading the closed-door signal correctly.