- Empty the fluid reservoir. Remove the mop pad. Unplug the power cord.
- Place the device with its underside facing up on your workspace.
- Remove the four screws on the grey mop pad bracket.
- Lift the grey bracket off.
- Remove the eight screws underneath the grey bracket.
- Use a pointed tool to peel off the rubber cap on the underside.
- Remove the screw underneath.
- Turn the device over.
- Carefully lift the top cover slightly. Be careful not to strain the cables underneath too much.
- Remove the two cable bundles from their retaining clips.
- You can now flip up the top cover to access all the components inside.
- Pay special attention to the blower motor; it sits loosely between two soft rubber seals. It must be tightly enclosed again during reassembly.