Opening the Ecovacs Winbot W1 PRO

ID: 240044

Description: For most repairs, you will need to open the...

Steps:

  1. Empty the fluid reservoir. Remove the mop pad. Unplug the power cord.
  2. Place the device with its underside facing up on your workspace.
  3. Remove the four screws on the grey mop pad bracket.
  4. Lift the grey bracket off.
  5. Remove the eight screws underneath the grey bracket.
  6. Step image Step image
  7. Use a pointed tool to peel off the rubber cap on the underside.
  8. Remove the screw underneath.
  9. Turn the device over.
  10. Carefully lift the top cover slightly. Be careful not to strain the cables underneath too much.
  11. Step image Step image
  12. Remove the two cable bundles from their retaining clips.
  13. You can now flip up the top cover to access all the components inside.
  14. Pay special attention to the blower motor; it sits loosely between two soft rubber seals. It must be tightly enclosed again during reassembly.
  15. Step image