Honeywell HY-204 Rotation Button Replacement
ID: 32061
Description: This guide shows how to replace the rotation...
Steps:
- Before you begin, be sure to unplug the fan.
- Remove the four 14 mm screws from the back of the device using the Phillips #0 Screwdriver.
- Pull the front and back parts of the case away from each other until the back is free from the front. This may require a large amount of force.
- Remove the two 3mm screws found just below the top of the device using the Phillips #0 Screwdriver.
- Pry off the control panel by forcefully lifting the tab located inside the front of the fan with the plastic opening tool.
- Remove the two 10mm Phillips #0 screws that are located next to the rotation button.
- Peel back the heat shrink tubing on both wires connecting to the button.
- Caution The soldering iron is very hot, be careful to avoid burns.
- Desolder the two wires connected to the button and remove the button.