TotalPond Pond Pump Impeller Replacement
ID: 37664
Description: The pumps impeller is responsible for...
Steps:
- Hold the inlet screen and rotate it counterclockwise to unscrew it. It is helpful to remove the inlet screen so that it is not damaged during the replacement process.
- Firmly hold the pump block with one hand and the impeller housing with the other hand. Rotate impeller housing counterclockwise until it is released.
- Remove the rubber stop that is attached to the tube that runs through the middle of the impeller. Also remove the bearing that is between the stop and the impeller.
- Hold the impeller cover with one hand and the impeller with the other. Slide the impeller out.