Canon EOS Rebel T2i Dioptric Adjustment Lens Replacement
ID: 40741
Description:
Steps:
- Before beginning, ensure that the camera is off, and the battery is removed.
- Pry open the rubber I/F terminal cap with your finger.
- Remove the two M1.7x2.5mm JIS #000 screws that are underneath the I/F terminal cap.
- Using a plastic pick, or another thin plastic prying tool, pop off the I/F terminal cover from the camera.
- On the left side of the camera, remove the following screw:
- One M1.7x6.0mm JIS #000 screw
- On the right side, remove the following screws:
- One M1.7x5.5mm JIS #000 screw
- One M1.7x3.5mm JIS #000 screw
- Remove the battery door.
- Open the battery door to about a 35° angle.
- Pull the battery door straight outwards.
- Remove the following screws from the bottom of the camera:
- One M1.7x6.0mm JIS #000 screw
- Two M1.7x2.5mm JIS #000 screws
- One M1.7x5.5mm JIS #000 screw
- Slide the viewfinder eyepiece vertically upwards.
- Start to pull the back cover partially off of the camera.
- Use caution when removing the back cover, there is a ribbon cable that connects the LCD screen to the main PCB board.
- Disconnect the LCD screen ribbon cable from the main PCB board.
- Use a plastic spudger to lift up the black locking tab.
- Carefully pull out the ribbon cable from its connector using a pair of angled tweezers.
- Finish pulling the back cover off of the camera body.
- Remove the following screws from the front of the camera:
- Two M1.7x5.5mm JIS #000 screws
- On the bottom of the camera, remove the following screws:
- Three M1.7x5.5mm JIS #000 screws
- Slide a spudger tool towards the tripod mount, underneath the plastic cover.
- Push the plastic cover up and over the tripod mount.
- Pull the front cover off of the camera.
- Electric Shock Warning: With the front cover off, the high voltage capacitor on the DC PCB board is now exposed. It is recommended that you use a capacitor discharge tool to ensure the capacitor is fully discharged before proceeding further.
- Remove the screws next to the viewfinder:
- Two M1.7x2.5mm JIS #000 screws
- One M2.0x8.9mm JIS #000 diopter screw
- Remove the following screws from the top of the camera:
- One M1.7x2.5mm JIS #000 screw
- One M1.7x5.0mm Phillips #000 screw
- Disconnect the microphone cable from the main PCB board.
- Position a flathead 2.5mm screwdriver between the main PCB board connector and the microphone connector.
- Gently wiggle the flathead screwdriver back and forth until the microphone connector comes free.
- If you do not have a flathead 2.5mm screwdriver, another similarly sized flathead screwdriver should work.
- Locate the ribbon cable which connects the top cover the main PCB board.
- Use a plastic spudger tool to carefully pry off the connector.
- Use caution when handling ribbon connectors and their connectors.
- Take note of where this fiber optic cable connects to the main PCB board.
- The cable will slide out of the connector when you pull the top cover off. You will need to remember to slide this cable back into the connector with a pair of tweezers when reinstalling the top cover. This cable is crucial for the function of the camera flash.
- Disconnect these two cables connected to the DC PCB board.
- Use the same method as with removing the microphone cable, except with using a flathead 3.0mm screwdriver.
- Gently wiggle the flathead screwdriver back and forth until the connectors comes free.
- If you do not have a flathead 3.0mm screwdriver, another slightly larger flathead screwdriver should work.
- Gently lift the top cover up and off of the camera body, being careful that the loose cables do not snag on anything.
- Remove the red wire that travels across the mirror box.
- Remove the following screws holding the mirror box in place:
- Four M1.7x4.5mm Phillips #000 screws
- Remove three JIS #000 screws to disconnect the ribbon mount assembly
- Now that the top assembly is free, this exposes another screw on the right side of the mirror box.
- Remove the following screw:
- One M2.0x4.3mm JIS #000 screw
- Remove the orange ribbon cable.
- Remove the viewfinder assembly from the camera. The screws that hold the eyepiece in place are accessible. Remove these three JIS #000 screws from the rear face of the eyepiece. Two screws are located at the bottom and one screw is located on top.
- With the screws removed, the eyepiece can easily be pulled free.
- Swivel the dioptric lens 90 degrees.
- Remove pin with tweezers.
- Compress spring and remove spring and dioptric lens assembly