Garmin Vivoactive Display Unit Replacement
ID: 52245
Description: If the Vivoactive's display unit is cracked or ...
Steps:
- Hold the the metal screwdriver, with a T5 Torx bit, in your dominant hand.
- Hold the rubber screwdriver, with a Hex T6 Torx bit, in your other hand.
- While holding the rubber screwdriver in place, simultaneously unscrew the pin (counterclockwise) with the metal screwdriver in your dominant hand.
- Once the 1mm screw is removed, reinsert the metal screwdriver in that same hole.
- Gently push the strap's pin out. It will begin to protrude from the other end.
- Use your fingers to grab the exposed pin and slide it free. The strap should now be disconnected from the device.
- Place a heated iOpener over the display to loosen the adhesive.
- After about a minute, the iOpener may be removed.
- For more in depth instructions on using the iOpener, refer to the iOpener guide.
- Place the blue plastic opening tool in-between the screen and plastic casing of the watch and slowly pry up one side of the screen.
- Once the first side has come free, wedge the blue pick in between the screen and watch unit on that side.
- Complete one pass around the perimeter of the screen to break the adhesive bond on all four sides.
- Insert it a minimal distance to avoid damaging internal components.
- Use the blue plastic opening tool to pry up the side of the glass. Raise it to a point where your fingernail can fit in the gap.
- Do the same on the opposite side of the device until you have a good grip of the screen.
- Obtain a careful grip of the screen from two of its sides.
- Slowly lift the screen off of the case. Separate it just enough so as not to damage the connection to the motherboard.
- Detach the orange tab that connects the screen to the motherboard with a gentle uplift using a plastic opening tool.
- Upon completing this step, the screen should be free from the rest of the device.