Fahrenheit FHT 125PRMR Power Cord Replacement

ID: 72934

Description: Is the device not turning on when plug in? This...

Steps:

  1. Use your fingers or a plastic opening tool to open the side hinges on both sides of the device.
  2. Step image
  3. Using a Philips head #2 screwdriver remove the 7mm black screw from the hinge of the device.
  4. Step image
  5. Using the metal spudger, push through the hole the screw was removed from. Doing this will push the copper pin out of the other side.
  6. When the pin is removed the two sides of the device can now separate.
  7. Be sure to collect the spring that is next to the hinge when they are separated.
  8. Step image Step image
  9. Use the Phillips Head 1 screwdriver to remove the two screws on the back where the power cable exits the device.
  10. Once the two screws are removed; simply lift the case up and off to have access to the power cable.
  11. Step image Step image
  12. To remove the power cable, grab the clear plastic holding and the base of the power cable and pull apart.
  13. Step image