Lopping Shears Wolf RS 870 Vario Knife and Anvil Replacement

ID: 144556

Description: In these instructions, the replacement of the...

Steps:

  1. Loosen the two 5 mm hexagon socket screws on the anvil. They are quite tight due to the threadlocker. Make sure that the wrench is correctly seated in the screw.
  2. Lift the anvil up and insert a new one.
  3. Close the shears so that there is no gap between the blade and the anvil and tighten the screws. Optionally, you can use some new threadlocker varnish.
  4. Step image Step image
  5. To replace the blade, loosen these two 5 mm Allen screws. These are also quite tight due to locking varnish.
  6. The screw marked in red has a round collar. Put them back in the right place.
  7. Pull out the counter bushings downwards and remove the knife with the lever (called a Koppe)
  8. Make sure that the new blade rests against the anvil without a gap and reinsert the bushings. Replace the screws and make sure that the ring of the tie rod is centered in the round screw collar. Tighten both screws. If necessary, you can use a little threadlocker varnish.
  9. Step image Step image Step image