Rowenta Focus Heating Element and Soleplate Replacement
ID: 145463
Description: If the metal soleplate on the Rowenta Focus...
Steps:
- Using a T20 screwdriver, remove the 20 mm screw on the back of the iron.
- Unplug iron before removing cover and make sure the iron is cool before beginning the repair.
- Pry the back cover of the iron off using a metal spudger.
- Remove the back cover, exposing the wiring in the iron.
- Remove the frontmost (main) power cord to give access to inner wiring and accessories.
- Leave the other cords attached to the main cord.
- Pull out the motherboard inside handle of iron.
- Keep it attached to main power cord and other components.
- Remove the 4-pronged adaptor from inside the iron by grabbing the black plastic piece and pulling straight out.
- Insert the metal spudger into the space between the spray/steam button piece and the rest of the iron.
- Using the metal spudger for leverage, pry the piece away from the rest of the iron until it can be lifted out.
- Lift out the piece.
- Replace with an identical part by inserting it into the space.
- Using the T20 screwdriver, remove the 20 mm screw that was under the steam and spray button.
- Unhook the clips on the top of the metal piece.
- Using the metal spudger, remove the metal piece on the tip of the iron.
- Using the T20 screwdriver, remove the 20 mm screw that was under the metal piece on the tip of the iron.
- Using the T20 screwdriver, remove the two 20 mm screws on either side of the back of the iron.
- Lift the iron up using the handle to completely detach the soleplate.