Jura Capresso IMPRESSA J5 Flowmeter exchange/replacement

ID: 147633

Description: The flowmeter measures how much water is...

Steps:

  1. Unplug the power cord!
  2. Remove the water tank and the drip tray. Remove all coffee beans from the storage container.
  3. Step image
  4. Flip open the lid of the bean compartment.
  5. Unscrew the two slotted screws inside the bean compartment. The screws have a rubber washer and will not come out completely.
  6. Remove the bean compartment.
  7. Step image Step image Step image
  8. The top cover is fastened with oval head screws. Unscrew them.
  9. These screws have an oval head that makes them look like rivets (picture 2). You need to use a special bit - also available at iFixit - for their removal. Here a DIY guide. If the right bit is not available, it could be done with a pair of needle nose pliers. Jura wants to keep us out of our own machines!!!
  10. Step image Step image Step image
  11. Also remove the two oval head screws underneath the ground coffee compartment lid.
  12. Step image
  13. Now you can pry up the top cover all around.
  14. Remove the top cover. This often requires a little force.
  15. Use plastic tools to avoid scratching your device.
  16. Step image
  17. Turn the device with the back facing you.
  18. Turn the Jura label a few degrees counterclockwise. If it's hard to do, use a small suction cup.
  19. Remove the Jura label.
  20. Step image Step image
  21. Underneath the label you will find two Torx T15 screws. Remove them.
  22. Carefully pull the top of the chrome cover slightly outwards, then push it down and put it aside.
  23. Step image Step image Step image
  24. Remove the Torx T15 screw on the side panel with the water tank.
  25. Step image
  26. Pull the right side panel slightly towards the back.
  27. Remove the side panel.
  28. Step image Step image
  29. Pull the left side panel slightly towards the back and remove it.
  30. Step image
  31. The motor for the drainage valve is located in the lower side of the unit near the center. It is fastened with three screws and connected with several flat plugs. In the picture, the ceramic valve has already been pushed off.
  32. Note: models from J6 onwards have a motor installed and not a magnet.
  33. Step image
  34. Unscrew the three Torx T15 screws on the motor for the drain valve. Pay attention to the washers underneath.
  35. Carefully pull out the motor.
  36. If you want to replace it, you still have to disconnect the flat connectors. Note where the connectors are connected.
  37. Step image Step image Step image
  38. The flowmeter is inserted in the front area of the device next to the brewing group. The inlet on the front is easy to see and can be carefully pushed off.
  39. Step image Step image
  40. The drain at the back is not so easily accessible. Turn the machine over so the heat exchanger is in front of you.
  41. Pull the hose off the heat exchanger. It leads directly to the flow meter.
  42. Now the drain hose from the flow meter is free, just detach it from its guides.
  43. Step image Step image
  44. Turn the machine over again.
  45. Carefully remove the flowmeter.
  46. Step image
  47. Blow into the lower inlet nozzle of the flow meter. You should hear the turbine whirring nicely.
  48. The flowmeter can be opened easily. Twist the top clockwise a little and take it off. Pay attention to the gasket when assembling.
  49. The inlet channel is very thin, this is where most of the dirt settles. Take a needle and poke the opening.
  50. Clean the flowmeter well and put it back together
  51. Step image Step image
Back