DeLonghi ECAM Series power board replacement

ID: 155596

Description: If the device cannot be switched on at all, the...

Steps:

  1. Unplug the power cord!
  2. Remove all attachments such as water tank, pulp drawer, brew group.
  3. Turn the machine with the back facing you.
  4. Remove five Torx T20 security screws.
  5. A small hurdle: These screws have a pin in the middle, so the screwdriver must have a hole.
  6. Step image
  7. Lift out the back.
  8. The following components are immediately visible:
  9. grinder
  10. pump
  11. flowmeter
  12. Step image Step image
  13. Also slide the cover - if not already done - on the water tank side backwards and remove it.
  14. Step image
  15. The power board is located under the cover. It is fixed with four screws in the corners and connected with a lot of cables.
  16. Move the cables a bit to the side and unscrew the four Phillips screws in the corners.
  17. Step image
  18. The cables have many different connectors and can almost not be confused. Make a special note of where the flat connectors are connected.
  19. The flat connectors can be disconnected more easily if you lift the cover in the corner of the device to the side.
  20. Lift the board out a few centimeters.
  21. Carefully loosen all connections. Some are secured with latches that you have to push away first.
  22. Step image Step image