DeLonghi ECAM Series power board replacement
ID: 155596
Description: If the device cannot be switched on at all, the...
Steps:
- Unplug the power cord!
- Remove all attachments such as water tank, pulp drawer, brew group.
- Turn the machine with the back facing you.
- Remove five Torx T20 security screws.
- A small hurdle: These screws have a pin in the middle, so the screwdriver must have a hole.
- Lift out the back.
- The following components are immediately visible:
- grinder
- pump
- flowmeter
- Also slide the cover - if not already done - on the water tank side backwards and remove it.
- The power board is located under the cover. It is fixed with four screws in the corners and connected with a lot of cables.
- Move the cables a bit to the side and unscrew the four Phillips screws in the corners.
- The cables have many different connectors and can almost not be confused. Make a special note of where the flat connectors are connected.
- The flat connectors can be disconnected more easily if you lift the cover in the corner of the device to the side.
- Lift the board out a few centimeters.
- Carefully loosen all connections. Some are secured with latches that you have to push away first.