Steps:
- Never forget: Remove the cable from the powerplug
- Remove all the parts
- The backside is fixed with seven Torx T10 screws. Unscrew them
- Get the Backside of. It should be a bit stuck.
- Pull the powder compartment up.
- Pull one of the sides of the Powder compartment out of the hinge and loosen the lid.
- Remove the powder compartment
- In the powder compartment, you should see a rubber cover. Loosen the rubber cover with the appropriate tools.
- There should also be a Torx T10 screw. Unscrew it
- The upper cover with the brewing unit is held up from three clamps. These can be reached through a slit.
- Press these clams with a flat scredriver in and pull the upper cover up, until the clamps loosen.
- On the side that has a a watertank you can find 2 other clamps
- Press these clamps with a flat scredriver in and pull the cover up until they loosen
- Lift the upper cover and the backside up, hook it on the front edge and remove them
- Push the right and the left side panel back, then pull the lower edge out and pull the side panel out.
- This could be a bit stuck
- On the side panel with the watertank, there should be a supply hose attached to a cable that connects the water-level sensore. loosen them
- Hint: the side panel doesn't have to be removed completely for each repair.