WMF Stelio milk frother does not heat up - replace the NTC thermal sensor

ID: 182305

Description: WMF Stelio milk frother no longer heats up....

Steps:

  1. Function check: Operating indicator flashes red. No heating. Press twice = stirring cold is OK.
  2. Open the device: 3 screws on the base (feet). Check the heating loop and thermal fuses: approx. 120 ohms = OK. Relay does not switch on. Power supply to the electronics is OK.
  3. Check the thermal sensor: approx. 600 ohms (no change with temperature change...defective)
  4. Step image
  5. The NTC thermal sensor remains low-resistance throughout, which is why the heating does not switch on. Determine the switch-on value using a test potentiometer.
  6. The cut-off point is determined by repeated testing (starting) while changing the resistance value: 30 kOhm, i.e. the electronics switch the heating off at R<30kOhm and turn it on at R>30kOhm.
  7. A suitable NTC is one with R25=100KOhm and B=3950K. This has approximately 30 kOhm at approx. 60°C. (Type: F58-100K-B3950-1%- DO35 housing, a few cents).
  8. New, identical NTC installed in the sensor cable.
  9. Step image Step image
  10. Reinstall the NTC sensor with insulating tubing and thermal paste.
  11. Reassemble the device. Perform a function check and VDE test.
  12. Step image Step image Step image