WMF Stelio milk frother does not heat up - replace the NTC thermal sensor
ID: 182305
Description: WMF Stelio milk frother no longer heats up....
Steps:
- Function check: Operating indicator flashes red. No heating. Press twice = stirring cold is OK.
- Open the device: 3 screws on the base (feet). Check the heating loop and thermal fuses: approx. 120 ohms = OK. Relay does not switch on. Power supply to the electronics is OK.
- Check the thermal sensor: approx. 600 ohms (no change with temperature change...defective)
- The NTC thermal sensor remains low-resistance throughout, which is why the heating does not switch on. Determine the switch-on value using a test potentiometer.
- The cut-off point is determined by repeated testing (starting) while changing the resistance value: 30 kOhm, i.e. the electronics switch the heating off at R<30kOhm and turn it on at R>30kOhm.
- A suitable NTC is one with R25=100KOhm and B=3950K. This has approximately 30 kOhm at approx. 60°C. (Type: F58-100K-B3950-1%- DO35 housing, a few cents).
- New, identical NTC installed in the sensor cable.
- Reinstall the NTC sensor with insulating tubing and thermal paste.
- Reassemble the device. Perform a function check and VDE test.