Ariston Velis Evo troubleshooting probes and repair
ID: 205054
Description: This manual shows how to test the temperature...
Steps:
- The boiler does not heat water, all LED's flash for a few seconds and then turn off. After switching on, the LED's flash again.
- There is no relay click when turned on.
- While the lights are lighting up, press and hold the power button until one, two, or three lights remain lit steadily.
- The processor will display an error code, with 40 degrees being code 1, 50 degrees being code 2, and so on up to 5.
- If the code is number 3 (60 degrees), it means that one or both temperature sensors are faulty.
- Error codes: 1 or 1&3 - defective electronics, 3 or 2&3 - faulty temperature probe, 5 or 2&5 - one sensor has read too high temperature, 4&5 or 2&4&5 - excessive temperature (electronic failure), 2&3&4&5 or 3&4&5 - excessive heating due to lack of water, 3&4 or 2&3&4 - faulty heater.
- Turn off the mains switch and make sure there is no voltage at the input contacts (L and N).
- Remove the screen by using a flathead screwdriver to pull it towards you from the bottom and then from all other edges.
- Remove the probe connector from the display electronics. The probes differ in width (8 and 10mm), do not interchange them!
- Measure the resistance between the red and yellow contacts, as well as the red and brown wires, with a multimeter. The resistance at pair of pins should be about 12 KOhm and about 14 KOhm at a temperature of about 20 degrees Celsius.
- If any of the resistances differ significantly from those specified, the probe is defective and should be replaced.
- Disconnect the probe and pull it out.
- Put a new probe but do not bend it or you may damage it!
- Connect the probe to the display electronic.
- Connect the mains and push the power button. Now it should work as normal.
- If display is still flashing and there is no clicking sound from relays, the main electronics should be checked and possibly replaced.
- If the screen works normally, but the water does not heat up even a little in 20 minutes, the heaters should be checked.
- The resistance at the heater contacts should be about 36 Ohms and infinite Ohms between the contact and the heater housing.