Withings ScanWatch (Gen 1): Open the Case

ID: 220043

Description: Open the Withings ScanWatch (1st generation)...

Steps:

  1. The watch is held together by friction and a thin black gasket. There are no screws or glue.
  2. Place a thin metal smartphone opening tool between the metal case and the glass/display side of the watch, not on the sensor side.
  3. Work your way around the watch carefully to release the gasket.
  4. Step image
  5. Once the watch is open, you can see the movement and a small cable connecting the sensor to it.
  6. The cable has an iPhone-like connector and can be released with a plastic spudger.
  7. Carefully pry the connector straight up to avoid damage.
  8. Do not pull on the cable. Disconnect the connector first.
  9. Step image
Back