How to Troubleshoot Power Supply in a Dryer
ID: 221356
Description: [youtubevideo|ty4Bu-iwJJM]Use this guide to...
Steps:
- Gather a multimeter, a flathead screwdriver, and a Phillips screwdriver.
- Use a multimeter with intact probes and a voltage rating suitable for household power.
- Electric dryers use 240 volts AC, which can seriously injure or kill you.
- Keep your fingers on the insulated parts of the probes and away from metal terminals, prongs, and slots.
- Work on a dry floor with dry hands, and stop if you are not comfortable testing live voltage.
- Move the dryer far enough to reach the back panel where the power cord enters the cabinet.
- Remove the cover plate over the power-cord connection with a screwdriver.
- Identify the three terminal-block screws where the cord wires connect to the dryer.
- The two outside screws are the hot terminals, and the center screw is neutral.
- Plug the dryer in and set the multimeter to AC volts.
- Touch one probe to the left screw and the other to the center screw; the meter should read about 120 volts AC.
- Touch one probe to the center screw and the other to the right screw; the meter should read about 120 volts AC.
- Touch one probe to each outside screw; the meter should read about 240 volts AC.
- Do not let the probe tips slip or touch two terminals at the same time.
- If all three readings are correct, the dryer is getting proper incoming power and the fault is inside the dryer.
- If a 120-volt or 240-volt reading is missing, unplug the dryer and continue testing toward the outlet and breaker.
- Unplug the dryer before testing the power cord for continuity.
- Set the multimeter to continuity or resistance mode.
- Touch one probe to a terminal-block screw and the other to the matching prong on the dryer plug.
- Repeat this check for the other outside terminal and for the center terminal to its matching neutral or ground prong.
- A beep or low resistance means that wire in the cord has continuity.
- An open or no-continuity reading means that prong does not connect to its wire, so the dryer cord should be replaced.
- If the cord tests good but the dryer still is not getting proper voltage, continue with the wall outlet.
- Leave the dryer unplugged and set the multimeter to AC volts.
- Look at the dryer outlet and identify whether it has three prongs or four prongs.
- A three-prong outlet has two flat hot slots and one neutral slot.
- A four-prong outlet has two outside hot slots plus separate neutral and ground slots.
- Insert the probes far enough to touch the metal contacts inside the outlet slots.
- Keep your fingers away from the metal probe tips and outlet openings during these checks.
- Place one probe in the neutral slot and the other in one flat hot slot; the meter should read about 120 volts AC.
- Move the probe from the first hot slot to the other flat hot slot while keeping the other probe in neutral.
- The meter should read about 120 volts AC on the second hot-to-neutral test as well.
- Place one probe in each flat hot slot; the meter should read about 240 volts AC.
- If all three readings are correct, the outlet is supplying proper voltage.
- If any reading is missing, the outlet may have a loose, burned, or disconnected wire, or the breaker may be faulty.
- Identify the two outside flat slots on the four-prong outlet; these are the hot slots that provide 240 volts between them.
- Test one outside hot slot to the neutral slot; the meter should read about 120 volts AC.
- Test the same hot slot to the ground slot; the meter should also read about 120 volts AC.
- Repeat both 120-volt tests from the other outside hot slot to neutral and ground.
- Place one probe in each outside hot slot; the meter should read about 240 volts AC.
- If any required reading is missing, inspect the outlet wiring and breaker next.
- Find the circuit breaker that controls the dryer outlet and switch it off.
- Confirm that the outlet is dead before removing it from the box.
- Remove the outlet cover and pull the outlet from the electrical box with a screwdriver.
- Inspect the wires on the back of the outlet for burned ends, loose connections, or disconnected wires.
- Repair damaged outlet wiring before using the dryer again.
- Have a qualified electrician repair outlet wiring if you are not trained to do it safely.
- Go to the breaker panel and identify the double-pole breaker that controls the dryer.
- Switch the breaker fully off, then back on, to reset a tripped breaker.
- Do not remove the panel cover or touch internal panel parts unless you are qualified to work inside a live electrical panel.
- With the breaker off, a voltage test from either breaker screw to metal ground or neutral should show no voltage.
- With the breaker on, each breaker screw to metal ground or neutral should read about 120 volts AC.
- With the breaker on, testing across the two breaker screws should read about 240 volts AC.
- Replace the breaker if it does not provide about 240 volts AC across the two breaker screws while switched on.
- If the breaker output is correct but the outlet readings are wrong, the problem is between the breaker and the outlet.
- If the outlet and cord test good but the terminal-block readings are wrong, inspect the cord connections at the dryer.
- If the terminal block shows about 120 volts from each hot to neutral and about 240 volts hot to hot, continue troubleshooting inside the dryer.
- A dryer that runs, shuts off, and later runs again may have an overheating breaker, but a failing motor is also a common cause.